RX 450h AWD V6-3.5L (2GR-FXE) Hybrid (2011)
Voltage Inverter: Service and Repair
Installation
HYBRID / BATTERY CONTROL: INVERTER WITH CONVERTER: INSTALLATION
1. INSTALL HIGH VOLTAGE FUSE
CAUTION:
Wear insulating gloves.
(a) Remove the 11 bolts and inverter cover from the inverter with converter assembly.
NOTICE:
Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.
(b) Place the high voltage fuse as shown in the illustration.
HINT
Either the location shown in the illustration or other methods can be used to hold the high voltage fuse for the subsequent step.
(c) Install the high voltage fuse with 2 new nuts.
Torque : 4.2 Nm (43 kgf-cm, 37 in-lbf)
NOTICE:
Be sure to use a torque wrench to tighten the nuts.
(d) Install the high voltage fuse with 2 new nuts.
Torque : 4.2 Nm (43 kgf-cm, 37 in-lbf)
NOTICE:
Be sure to use a torque wrench to tighten the nuts.
(e) Temporarily install the inverter cover with the 11 bolts to prevent any foreign objects or water from entering the inverter with converter
assembly.