lexus Workshop Repair Guides

Lexus Workshop Service and Repair Manuals

ECT & ECU - Service for New Double Locking Connectors|Page 1002 > < ECT & ECU - Service for New Double Locking Connectors
Page 2
background image

1.

PREPARE THE SPECIAL TOOL

To remove the terminal from the connector, use SST #00002-217958, or construct a tool to the dimensions listed in Figure 1.

Disconnect the Male and Female Connector

2.

DISCONNECT THE MALE AND FEMALE CONNECTOR

^

For 40P Connector (Figure 2):

a)

Press down locking arm on the female connector body.

b)

Pull the female connector forward.

^

For 80P (fixed bolt) connector (Figure 3):

a)

Loosen and remove bolt.

b)

Pull female connector forward.

Disengage the Terminal Connector