SC 300 L6-3.0L (2JZ-GE) (1992)
1.
PREPARE THE SPECIAL TOOL
To remove the terminal from the connector, use SST #00002-217958, or construct a tool to the dimensions listed in Figure 1.
Disconnect the Male and Female Connector
2.
DISCONNECT THE MALE AND FEMALE CONNECTOR
^
For 40P Connector (Figure 2):
a)
Press down locking arm on the female connector body.
b)
Pull the female connector forward.
^
For 80P (fixed bolt) connector (Figure 3):
a)
Loosen and remove bolt.
b)
Pull female connector forward.
Disengage the Terminal Connector