Starter Relay: Testing and Inspection
Relay Continuity Test

Fig. 5 Relay continuity test connection locations

1.

Using an ohmmeter, check for continuity between terminals 1 and 3, Fig 5.

2.

Ensure there is no continuity between terminals 2 and 4.

3.

If either test fails, replace relay.