SC 400 V8-4.0L (1UZ-FE) (1997)
Ignition Cable: Testing and Inspection
HIGH-TENSION CORDS INSPECTION
1. REMOVE HIGH-TENSION CORDS
2. INSPECT HIGH-TENSION CORD RESISTANCE
Using an ohmmeter, measure the resistance.
Maximum resistance: 25 K Ohms per cord
If the resistance is greater than maximum, replace the high-tension cord.
3. REINSTALL HIGH-TENSION CORDS