3 L4-2.3L (2004)
Variable Valve Timing Solenoid: Service and Repair
OIL CONTROL VALVE (OCV) REMOVAL/INSTALLATION [L3]
1. Disconnect the negative battery cable.
2. Remove the following parts.
^
Plug hole plate
^
Ignition coils
^
Oil control valve (OCV) connector
^
Ventilation hose
^
Cylinder head cover
^
Oil control valve (OCV)
3. Install in the reverse order of removal.
Tightening torque 8.0 - 11.5 Nm (81.6 - 117.2 kgf-cm, 70.9 - 101.7 inch lbs.)