3 L4-2.3L (2004)
Transmission Speed Sensor: Oscilloscope Patterns and Waveforms
INSPECTION USING AN OSCILLOSCOPE (REFERENCE)
Input/turbine speed sensor (+) signal
PCM terminals
-
1 M (+) - Negative battery terminal (-)
Oscilloscope setting
-
500 mV/DIV (Y), 1 ms/DIV (X), DC range
Vehicle condition
-
Idle after warm-up
Input/turbine speed sensor (-) signal
PCM terminals
-
1Q (+) - Negative battery terminal (-)
Oscilloscope setting
-
500 mV/DIV (Y), 1 ms/DIV (X), DC range
Vehicle condition
-
Idle after warm-up