If any brush is worn almost to or beyond the limit, replace all of the brushes.

Generator brush length

-

Standard: 22.5 mm {0.886 in}

-

Minimum: 5.0 mm {0.20 in}

Brush spring

1. Measure the force of the brush spring using a spring pressure gauge.

2. Read the spring pressure gauge at the brush tip projection of 2 mm {0.08 in}.

-

If not within the specification, replace the brush spring.

Generator brush spring force

-

Standard: 4.1-5.3 N {0.42-0.54 kgf, 1.0-1.1 lbf}

-

Minimum: 1.7 N {0.17 kgf, 0.38 lbf}

Rectifier (Using an analog circuit tester)

1. Inspect for continuity of the diodes using an analog circuit tester.

-

If not as specified, replace the rectifier.

Specification

Rectifier (Using a digital circuit tester)

1. Inspect for continuity of the diodes using a digital circuit tester. 

-

If not as specified, replace the rectifier.

Specification