6 L4-2.5L (2010)
Fuel Line Coupler: Service and Repair
Quick Release Connector Removal/Installation
QUICK RELEASE CONNECTOR REMOVAL/INSTALLATION [L5]
WARNING:
-
Fuel is very flammable liquid. If fuel spills or leaks from the pressurized fuel system, it will cause serious injury or death and facility breakage.
Fuel can also irritate skin and eyes. To prevent this, always complete the "Fuel Line Safety Procedure", while referring to the "BEFORE
SERVICE PRECAUTION".
CAUTION:
-
Disconnecting/connecting the quick release connector without cleaning it may cause damage to the fuel pipe and quick release connector. Always
clean the quick release connector joint area before disconnecting/connecting using a cloth or soft brush, and make sure that it is free of foreign
material.
Quick Release Connector Type
CAUTION:
-
There are two types of quick release connectors. Verify the type and location, and install/remove properly.
Type A Removal
CAUTION:
-
Be careful not to damage the pipe when unlocking the retainer.
NOTE:
-
When removing the quick release connector, either SST 49 E042 001 or 49 N013 103A (Part of 49 N013 1A0D) can be used.
When using SST 49 E042 001
NOTE:
-
If the quick release connector is removed, replace the retainer with a new one.
1. Complete the "BEFORE SERVICE PRECAUTION". See: Service Precautions/Vehicle Damage Warnings/Before Service Precaution
2. Set the SST parallel to the quick release connector.