6 V6-3.0L (2007)
Terminal Voltage Table (Reference) (Part 3)
Inspection Using an Oscilloscope (Reference)
Secondary gear rotating speed signal
TCM terminals
^
2L (+)-1P (-)
Oscilloscope setting
^
1 V/DIV (Y), 2.5 ms/DIV (X), DC range
Vehicle condition
^
Drive the vehicle at approx. 32 km/h (19.9 mph)