Blower Motor: Component Tests and General Diagnostics

Front Blower Motor Inspection [Full-Auto Air Conditioner]

FRONT BLOWER MOTOR INSPECTION [FULL-AUTO AIR CONDITIONER]

1. Connect battery positive voltage to blower motor terminal A, connect terminal B to ground, and then verify its operation.

-

If there is any malfunction, replace the blower motor.

Front Power Metal Oxide Semiconductor Field Effect Transistor (Power MOS FET) Inspection
[Full-Auto Air Conditioner]

FRONT POWER METAL OXIDE SEMICONDUCTOR FIELD EFFECT TRANSISTOR (POWER MOS FET) INSPECTION [FULL-AUTO
AIR CONDITIONER]

1. Remove the front power MOS FET.  See: Service and Repair/Front Power Metal Oxide Semiconductor Field Effect Transistor (Power MOS FET)

Removal/Installation [Full-Auto Air Conditioner]

2. Connect the front power MOS FET connector.

3. Connect the negative (-) lead of the tester to body ground.

4. Switch the ignition to ON.

5. By inserting the positive (+) lead of the tester into each front power MOS FET terminal, measure the voltage according to the terminal voltage

table. 

-

If there is any malfunction, inspect the parts under "Inspection item (s)".

-

If the parts under "Inspection item (s)" are found to be normal, replace the front power MOS FET.

Terminal Voltage Table (Reference)