mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Cowl Area - Wet Passenger Carpet, Inoperative Blower|Page 4678 > < Cowl Area - Wet Passenger Carpet, Inoperative Blower|Page 4672
Page 1
background image

Blower Motor Resistor: All Technical Service Bulletins
Cowl Area - Wet Passenger Carpet, Inoperative Blower

Category     

Applicable Model/s

14

1988 626/MX-6

Subject WATER LEAK FROM COWL AREA
Bulletin No. 059/88
Issued

10/17/88

Revised
DESCRIPTION

If you encounter a customer complaint pertaining to a wet floor at front passenger compartment or malfunction of the blower motor due to a burnt out 
blower motor resistor, refer to the following repair procedure. The problem may be due to water entering through the heater blower cowl under the cowl
grill (lower moulding).

REPAIR PROCEDURE

1.

Remove the right side baffle cover under the cowl grill (lower moulding).

2.

Install a new baffle cover with modified fasteners after applying 0.08 inch (2 mm) thick of repair sealant (B001 77 739) additionally onto the
originally applied sealant as shown.

NOTE:
a)

If the repair sealant (B001 77 739) is not available, use equivalent one.

b)

If the modified fasteners are not available, reuse the original fasteners applying a small amount of sealant under the fastener head.

Cowl Area - Wet Passenger Carpet, Inoperative Blower|Page 4678 > < Cowl Area - Wet Passenger Carpet, Inoperative Blower|Page 4672