626 ES V6-2.5L DOHC (1997)
Charge Lamp/Indicator: Testing and Inspection
Flowchart No. 2 Symptom Generator warning light does not illuminate with ignition switch at ON (engine stopped)
Possible cause
^
Damaged generator
^
Damaged instrument cluster
^
Open or short circuit in wiring harness
^
Poor connection of connector
Step 1
1. Disconnect the generator connector and connect ground to terminal B (W/B).
Warning Lamp Illumination
Action Chart
2. Turn the ignition switch to ON and verify that the warning light illuminates.
Step 2
1. Turn the ignition switch to LOCK and connect the generator connector.
2. Remove the instrument cluster.
3. Disconnect the instrument cluster connector.
Ohmmeter Connection
Action Chart
4. Check for continuity between terminal 3G (W/B) of the instrument cluster connector and ground.