626 ES V6-2.5L DOHC (1997)
ABS Main Relay: Testing and Inspection
Fail-Safe Relay
1. Measure the resistance between terminals C and D of the ABS relay connector.
^
Resistance: 60-100 ohms.
2. Check for continuity between terminals A and E and between B and E.
-
There is continuity between A and E.
-
There is no continuity between band E.
3. Apply 12 V between terminals D and C. Check for continuity between terminals A and E and between B and E.
-
There is continuity between B and E.
-
There is no continuity between A and E.