626 LX L4-2.0L DOHC (1999)
Refrigerant Pressure Sensor / Switch: Service and Repair
REFRIGERANT PRESSURE SWITCH REMOVAL/INSTALLATION
1. Discharge the refrigerant from the system.
2. Disconnect the negative battery cable.
3. Remove the radiator grille and splash shield.
CAUTION: If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always,
immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.
4. Remove in the order indicated in the table.
5. Install in the reverse order of removal.
6. Recharge with refrigerant.
7. Perform the refrigerant system performance test.
Refrigerant Pressure Switch Installation Note
Apply compressor oil to the O-ring and connect the joint.
HI
LO