626 LX L4-2.0L DOHC (1999)
Starter Motor: Testing and Inspection
Starter
STARTER INSPECTION
On-vehicle Inspection
1. Verify that the battery is fully charged.
2. Crank the engine and verify that the starter turns smoothly without any noise.
3. Measure the voltage at terminals S and B when the ignition switch is in START position.
-
if the voltage is within the specification, remove the starter and inspect the magnetic switch and the starter.
-
if the voltage is not as specified, inspect the wiring harness, ignition switch, starter interlock switch (MTX), and transaxle range switch (ATX).
Specification Above 8 V
No Load Test
1. Verify that the battery is fully charged.
2. Connect the starter, battery, voltmeter, and ammeter as shown.
3
Operate the starter and verify that it turns smoothly.
FS = 2.0L 4CYL AND KL = 2.5L V6
4. Measure the voltage and current while the starter is operating.
If not as specified, repair or replace the inner parts as necessary.