Temperature Sensor (Gauge): Service and Repair

Removal/Installation

1. Disconnect the water temperature sender unit connector.
2. Remove the water temperature sender unit.

3. Before installing the unit, apply sealant from the third thread to the top thread.
4. Install in the reverse order of removal.

Tightening torque: 

11.8-17.6 N.m

{120-180 kgf.cm, 105-156 in.lbf}