background image

5. Tighten the intake manifold bolts in two steps and in the sequence shown.

1. Tighten to 10 N.m (89 lb-in).
2. Tighten to 20 N.m (15 lb-ft).

6. Position back the intake manifold support bracket and install the bolt. Tighten the bottom nut.

7. Install the positive crankcase ventilation (PCV) valve into the valve cover.

8. Connect the evaporative emission hose.

Lower Intake Manifold|Page 1099 > < Lower Intake Manifold|Page 1097