mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

General Module|Testing and Inspection > < Computers/Controls - Correcting Programmable Parameters|Page 119
Page 2
background image

- The ignition switch is turned from OFF to RUN.
- The ignition switch is turned from OFF to ACC.
- A wake-up request is received from the remote anti-theft personality (RAP) module.

The GEM/CTM illuminates the interior courtesy lamps when any door is set ajar or is opened. The following are inputs used for controlling the courtesy
lamps:

- All door ajar switches (including liftgate).
- Illuminated entry request with RAP module.

All interior courtesy lamps are turned off when any of the following occurs:

- All the doors are closed and the illuminated entry feature is not active.
- The ignition switch is turned to RUN.
- Vehicle speed is over 8 kph (5 mph).

The GEM/CTM controls the interior lamps illuminated entry function with the interior lamp relay.

The RAP module sends a signal to the GEM on the illuminated entry request circuit to indicate a request to turn the illuminated entry feature ON or OFF
.

The GEM illuminates the interior lamps when an unlock signal is received from the RAP module. The illuminated entry feature will be canceled when
any of the following conditions are met:

25 seconds have elapsed since the illuminated entry feature was activated and the interior lamp control is not activated.
- The GEM receives a request from the RAP module (remote transmitter lock button pressed) and the courtesy lamp control is not activated.
- The ignition is in the RUN or START position and the interior lamp control is not activated.

The illuminated entry inputs are:

- Ignition switch in the key-in, ACC and RUN position.
- RAP illuminated entry request.

The GEM/CTM sleep mode outputs are:

- None (All circuits are deactivated during sleep mode).

If a change in any of the above inputs occur while the GEM/CTM is asleep, the GEM/CTM will wake up and monitor all of its inputs, and will have the
ability to activate any of its outputs.

The GEM module provides temporary power to the power windows for ten minutes after the ignition switch is moved from RUN to the OFF position. If,
during this ten-minute period, either front door is opened, the delayed accessory relay will be de-energized.

The GEM controls the one-touch down window feature. When the power switch for the driver window control is held down (between 0.04 and 0.4
second
) and then released with the ignition switch in RUN OR ACC, the driver window will automatically move to its full down position.

Only the driver window has this feature. Holding the driver window switch down longer allows the operator to stop the window as soon as the switch is
released.

General Module|Testing and Inspection > < Computers/Controls - Correcting Programmable Parameters|Page 119