mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Blower Motor > < Air Conditioning Switch|Description and Operation|Page 4047
Page 1
background image

Air Door Cable: Adjustments

Airflow Mode Cable

Set the airflow mode control lever to the DEFROST position. Install the airflow mode cable with the shutter lever on the heater unit pushed fully
forward. Attach the securing clip. Turn the blower switch to position 4 and make sure there are no air leaks from the center and floor outlets.

Temperature Control Cable

Set the temperature control lever to the COLD position. Install the temperature control cable with the shutter lever on the heater unit pushed fully
upward. Attach the securing clip. Make sure the temperature control lever move fully from the COLD to HOT position.

REC/Fresh Control Cable

Set the rec/fresh selector lever to the RECIRCULATE position. Install the rec/fresh cable with the shutter lever on the blower unit pushed fully
upward. Attach the securing clip. Make sure the rec/fresh selector move fully from the RECIRCULATE to the FRESH position.

Blower Motor > < Air Conditioning Switch|Description and Operation|Page 4047