mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Charge Air Cooler (CAC) Bypass Actuator Inspection|Page 2579 > < Charge Air Cooler (CAC) Bypass Actuator Inspection|Page 2577
Page 2
background image

1. Air intake pipe No.1
2. ABV actuator
3. Charge air cooler actuator
4. Air intake pipe No.2

Inspection

1. Remove the ABV actuator
2. Verify that the air does not flow through ports A and B.
3. Install the vacuum pump to port C.
4. Using the vacuum pump, apply vacuum over 33.3 kPa (250 mmHg, 9.84 inHg) and verify that air flows through ports A and B.
5. Increase vacuum and verify that the air flow volume increases accordingly.
6. If not as specified, replace the ABV actuator.

Charge Air Cooler (CAC) Bypass Actuator Inspection|Page 2579 > < Charge Air Cooler (CAC) Bypass Actuator Inspection|Page 2577