Millenia L V6-2.5L DOHC (1997)
Temperature Gauge: Testing and Inspection
Inspection
1. Remove the instrument cluster.
2. Connect battery positive voltage to terminal 2G and ground to terminal 21 of the instrument cluster.
3. Connect the positive (+) lead of the SST to terminal 2E of the instrument cluster and ground to the negative (-) lead.
4. Verify that the gauge indicates the values shown in the figure.
5. If not as specified, replace the combination gauge.