Millenia L V6-2.5L DOHC (1997)
![background image](/mazda/millenia_l/v6-2.5l_dohc/Page-1143001.png)
Selector Cable: Adjustments
1. Remove the air cleaner assembly.
2. Shift the selector lever to the park position.
3. Loosen nut (A) as shown in the figure.
4. Push the selector cable in the direction of the arrow until it doesn't move any further.
5. Position the selector cable so that there is no load in the direction of the arrows, and tighten the nut to 16 - 22 Nm (12 - 16 ft. lbs.).
6. Install the air cleaner assembly.
7. Shift the selector lever from park position to L range, and make sure that there is no interference from other components in that area.