Millenia S V6-2.3L DOHC (Miller cycle) (2000)
Coolant Temperature Sensor / Switch HVAC: Service and Repair
WATER TEMPERATURE SENSOR
1. Disconnect the negative battery cable.
2. Remove the under cover, glove compartment, and glove compartment cover.
3. Remove the stay.
4. Disconnect the water temperature sensor connector.
5. Remove the water temperature sensor.
6. Install in the reverse order of removal.