Millenia S V6-2.3L DOHC (Miller cycle) (2000)
following procedure with the engine stopped.
CAUTION: Connecting the wrong DLC terminal may possibly cause a malfunction. Carefully connect the specified terminal only.
1. Short DLC terminal F/P to body GND using a jumper wire.
2. Turn the ignition switch to ON to operate the fuel pump.
3. Pressurize the system this way for at least 5 minutes to be sure of no leakage.
-
If there is fuel leakage, inspect for damaged fuel hoses, hose clamps, and fuel pipe sealing surface and replace as necessary.
4. After repair, assemble the system and repeat Steps 1 to 3.