Condenser HVAC: Service and Repair

1. Disconnect the negative battery cable.
2. Discharge the refrigerant from the system.
3. Raise the front of the vehicle.
4. Remove the ambient temperature sensor.
5. Remove the radiator grille, mud guard (RH), splash shields (front), and hood stay.
6. Remove the radiator brackets and coolant reservoir.

7. Insert a protector (such as cardboard) between the condenser and the radiator, and lean the radiator toward the engine.

CAUTION:  If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always
immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.

8. Remove the assembled cooler pipe No.2, receiver/drier, and condenser. Do not allow compressor oil to spill. Immediately plug all open fittings to

keep moisture out of the system.

9. Remove in the order indicated in the table. Do not allow compressor oil to spill. Immediately plug all open fittings to keep moisture out of the

system.

10. Install in the reverse order of removal.
11. Perform refrigerant system performance test. 

Condenser Installation Note

When installing a new condenser, add ATMOS GU10 compressor oil into the refrigeration cycle.