Millenia S V6-2.3L DOHC (Miller cycle) (2000)
B.
Set the HVAC controls as follows.
^
RECIRCULATE
^
FULL HEAT
^
FAN HIGH
^
A/C OFF
^
AIRFLOW (FACE)
C.
Open one window approximately one half inch.
D.
Let the engine run for 15 minutes.
2.
Remove the glove box by:
A.
Pressing the damper stay in the direction shown by the arrow and detach it from the glove compartment lid.
B.
Bending the stoppers inward to remove.
C.
Turn the glove compartment downward and pull the pins.
3.
Stop the engine. Switch OFF the fan motor.