MPV DX V6-2.5L DOHC (2000)
Power Trunk / Liftgate Lock Switch: Testing and Inspection
LIFTGATE LOCK CYLINDER SWITCH INSPECTION
1. Disconnect the negative battery cable.
2. Remove the liftgate lower trim.
3. Disconnect the liftgate lock cylinder switch connector.
4. Inspect for continuity between the liftgate lock cylinder switch terminals using an ohmmeter.
-
If not as specified, replace the liftgate lock cylinder switch.