Shift Cable: Adjustments

SELECTOR CABLE ADJUSTMENT 

1. Remove the column cover.
2. Shift the selector lever to P position.

3. Loosen nut A shown in the figure.

4. Pull the selector lever to the R position side gate of P position, and tighten nut A.

Tightening torque
16 - 22 Nm (1.6 - 2.3 kgf.m, 12 - 16 ft. lbs.) 

5. Verify that the selector lever bolt end is exposed from the nut.
6. Install the column cover.

Torque Converter > < Shifter A/T|Testing and Inspection|Page 2672