MPV ES V6-2.5L DOHC (2001)
Keyless Entry Module: Testing and Inspection
KEYLESS CONTROL MODULE INSPECTION
1. Measure the voltage at the keyless control module terminals as indicated below.
2. Disconnect the keyless control module connector before inspecting for continuity at terminals C and L.
-
If not as specified, inspect the parts listed under "Action."
-
If the parts and wiring harnesses are okay but the system still does not work properly, perform the keyless entry system problem check.
Terminal Pinouts
Terminal A - N