Power Door Lock Actuator: Service and Repair
Liftgate Lock Actuator Removal / Installation
1. Disconnect the negative battery cable.
2. Remove the liftgate screen.
3. Disconnect the liftgate lock actuator connector.
4. Remove the liftgate lock actuator installation rod.
5. Remove the liftgate lock actuator installation nuts, and remove the liftgate lock actuator.
6. Install in the reverse order of removal.
Tightening torque: 6.87-9.80 Nm (60.8-86.7 in.lbs.)