Catalytic Converter: Testing and Inspection

NOTE:  Make sure that no HO2S DTC has been detected. If detected, this inspection cannot be used for TWC inspection.

1. Connect the NGS tester and monitor PIDs as following.

-

California emission regulation applicable models
-

Monitor the left WU-TWC using FHO2S L PID for upstream HO2S and RHO2S L PID for downstream HO2S.

-

Monitor the right WU-TWC using FHO2S R PID for upstream HO2S and RHO2S R PID for downstream HO2S.

-

Federal emission regulation applicable models
-

Monitor TWC using MHO2S PID for upstream H02S and RHO2S PID for downstream HO2S.

2. Press START to begin monitoring the appropriate PIDs.
3. Drive the vehicle for 10 minutes at 6.96 km/h {40 - 60 mph} to ensure the front catalytic converter reaches operating temperature.
4. Stop the vehicle and leave in a sate place.
5. Let the engine idle.
6. Press TRIGGER to begin recording PIDs.
7. Wait for 1 minute then press TRIGGER again to finish recording.
8. Select the appropriate PIDs and read the graph of "VIEW RECORDING".
9. Count the number of times (inversions) that the upstream HO2S graph line actually crosses the 0.5 V line.

10. Count the number of times (inversion) that the downstream HO2S graph line actually crosses the 0.5 V line.

NOTE:  Do not count the number of peaks. Refer to the illustration.

11. Using the following equation, calculate the value of ratio.

Upstream HO2S Graghline Example

Downstream HO2S Graphline Example 1

Equation
RATIO + Upstream HO2S inversion downstream HO2S inversion

-

If the ratio is 2 or more or no downstream H02S inversion, the WU-TWC is functioning properly.