MX-3 V6-1844cc 1.8L DOHC (1993)
Malfunction Indicator Lamp - A/T: Testing and Inspection
Inspection
Inspection of operation
1. Turn the ignition switch ON.
2. Verify that the HOLD indicator is not illuminated.
3. Depress the switch and verify that the HOLD indicator comes ON.
NOTE: If a malfunction occurs in any of the EC-AT system components, the HOLD indicator flashes.
4. If not as specified, check the continuity of the instrument cluster and check the hold switch.
Inspection of continuity
1. Disconnect the negative battery cable.
2. Remove the instrument cluster.
3. Check continuity of the instrument cluster.
4. If not as specified, remove the HOLD indicator lamp bulb at the rear of the instrument cluster.
5. If the bulb is burnt, replace it.
6. If the bulb is OK, replace the instrument cluster.
7. Install the instrument cluster.
8. Connect the negative battery cable.