MX-5 Miata L4-1597cc 1.6L DOHC (1992)
4.
Remove pipe "B" and install 560 mm tube. Refer to Fig. 4.
5.
Cut 40 mm out of the service part (vinyl tube)
6.
Install the 40 mm tube onto the "Y" connection. Refer to Fig. 4.
7.
Install check valve onto the 40 mm tube.
8.
Connect all lines and verify operation and that no leaks exist at the connections.
PROCEDURE 2 (TYPE B)
1.
Replace both joint pipes with check valves. Refer to Fig. 5.
NOTE:
Install the check valve so that the check ball faces the pump. If the valve is installed in the wrong direction, the washer fluid will not flow from the
nozzle.
2.
Connect all lines and verify operation and that no leaks exist at the connections.
PARTS INFORMATION