EGR Valve: Testing and Inspection
EGR Control Inspection

1. Verify that EGR valve operation (initial operation) sound is heard when the ignition switch is turned to ON.

-

If the operation sound is not heard, connect the SSTs (NGS tester) to DLC-2 and verify that DTC P1496, P1497, P1498 or P1499 is shown.
Carry out troubleshooting of DTC inspection.

2. Start the engine and run it at idle.

3. Select the SIMULATION TEST function on the NGS display.
4. Increase the step value of EGR valve from 0 to 40 using SEGRP. Operate the EGR valve and inspect if the engine speed becomes unstable or the

engine stalls.
-

If the engine speed will change, proceed to Step 11.

-

If the engine speed will not change, proceed to next step.

5. Stop the engine.
6. Remove the EGR valve.
7. Connect the EGR valve connector.
8. Turn the ignition switch to ON.

9. Select the SIMULATION TEST function on the NGS display.

10. Increase the step value of EGR valve from 0 to 40 using "SEGR P". Inspect the EGR operation.

-

If the EGR valve is operated, clean the EGR valve and reinspect from Step 3.

-

If the EGR valve will not operate, replace the EGR valve and reinspect from Step 3.

11. Warm up the engine to normal operating temperature.

12. On level ground, jack up the vehicle and support it evenly on safety stands or set the vehicle on the chassis roller.

Component Inspection|Page 1804 > < Component Inspection|Page 1802