Protege DX L4-1.6L DOHC (2000)
Hydraulic Control Assembly - Antilock Brakes: Testing and Inspection
ABS Hu/CM
ABS HYDRAULIC UNIT (HU)/CONTROL MODULE (CM) INSPECTION
1. Disconnect the negative battery cable.
2. Connect the SST between the ABS HU/CM and harness connector with the ignition switch off.
3. Attach the tester leads to the SST and inspect voltage referring the table below.