Protege DX L4-1489cc 1.5L DOHC MFI (1998)
2. Measure the resistance between a ground and the illustrated terminals at the ABS control module connector.
Resistance: approx. 3 - 5 ohms
3. If not as specified, inspect the wiring harness between the ABS hydraulic unit connector (8-pin) and the ABS control module, and inspect the
solenoid valves.
Solenoid Valve Inspection
1. Disconnect the ABS hydraulic unit connector (8-pin).
2. Measure the resistance between the following terminals. A - E, B - F, C - G, D - H
Resistance: Approx. 3 - 5 ohms
3. If not as specified, repair the hydraulic unit harness or replace the ABS hydraulic unit as necessary.