Shift Interlock Switch: Testing and Inspection
"P" Position Switch
P POSITION SWITCH INSPECTION
1. Disconnect the negative battery cable.
2. Remove the rear console and front console.
3. Remove the indicator panel screws and lift up the indicator panel.
4. Disconnect the P position switch connector.
5. Inspect for continuity between the terminals.
6. If not as specified, replace the P position switch.
7. Connect the connector.
8. Install and adjust the indicator panel.
9. Install the front console and rear console.
10. Connect the negative battery cable.