Protege DX L4-2.0L DOHC (2002)
Backup Lamp Switch: Testing and Inspection
BACK-UP LIGHT SWITCH INSPECTION
1. Disconnect the back-up light switch connector.
2. Inspect for continuity between the back-up light switch terminals using an ohmmeter.
-
If not as specified, replace the back-up light switch.