Protege ES L4-1839cc 1.8L DOHC (1997)
Radiator Cooling Fan Motor: Testing and Inspection
1. Verify that the battery is fully charged.
2. Disconnect the cooling fan motor connector
3. Connect battery positive voltage and ammeter to the cooling fan motor connector.
4. Verify that the cooling fan motor operates smoothly at the standard current draw for:
^
Manual Transaxle: 2.6-4.2 A
^
Automatic Transaxle: 5.2-7.2 A
5. If not, replace the cooling fan motor.