Alternator: Specifications
Generator Specifications

Generator Specifications 

Standard Voltage 

   

  

  

 

Terminal

Ignition Switch: ON (V) Idle (V) 

20 degrees C (68 degrees F)

 

   

  

  

 

B

B+

13-15 V 

   

  

  

 

P

Approximately 1 V

Approximately 3-8 V 

   

  

  

 

D

Approximately 0 V

Turn the following electrical loads on and verify that the

 

voltage reading increases; Headlights Blower Motor Rear

 

Window Defroster

 

   

  

  

 

Standard Current (Referance) 

Measuring Conditions: Room Temperature: 20 degrees C (68

 

degrees F) Voltage: 13.5 Engine Hot

 

   

      

      

 

Engine Speed (rpm)

Terminal B Current (A) 

   

  

      

 

1,000

0-59 A 

Must not be 0.

 

   

  

      

 

2,000

0-77 A 

Must not be 0.

 

   

  

      

 