mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Ignition Cable|Specifications|Page 1058 > < Ignition Cable|Specifications
Page 1
background image

Ignition Cable: Testing and Inspection

IGNITION CABLE INSPECTION

1. Measure the resistance of the high-tension leads by using an ohmmeter. 

Specification: 16 K ohms per 1.00 m (3.28 ft) 20°C (68°F) 

2. If not as specified, replace the high-tension lead.

Ignition Cable|Specifications|Page 1058 > < Ignition Cable|Specifications