Protege LX L4-1489cc 1.5L DOHC MFI (1998)
4.
Disconnect the purge hose (port side) from the adapter in the hose between the purge port and the purge solenoid as shown.
5.
Install the Open Vent Kit as shown. Be sure to use a tie-wrap and loosely secure the Vent Kit air filter hose to the brake booster hose.
6.
Verify repair.
PART(S) INFORMATION
WARRANTY INFORMATION
Note
This information applies to verified customer complaints on vehicles covered under normal warranty Refer to the SRT microfiche for warranty term