Protege LX L4-2.0L DOHC (2001)
Open circuit
-
Constant voltage circuit (TP sensor connector terminal A and PCM connector terminal 90)
-
TP signal circuit (TP sensor connector terminal B and PCM connector terminal 89)
-
GND circuit (TP sensor connector terminal C and PCM connector terminal 91)
Short circuit
-
Constant voltage circuit (TP sensor connector terminal A and PCM connector terminal 90)
-
TP signal circuit (TP sensor connector terminal B and PCM connector terminal 89)
5. Reconnect the TP sensor connector.