RX8 2RTR-1.3L (2006)
375-450 kPa {3.83-4.58 kgf/sq.cm, 54.4-65.2 psi}
11. Disconnect the jumper wire and stop the fuel pump.
12. Wait 5 min and measure the fuel hold pressure.
-
If it is within the specification, inspect the following
-
Fuel line for clogging or leakage
Fuel hold pressure
200 kPa {2.0 kgf/sq.cm, 29 psi}
13. Disconnect the SST.
14. Connect the quick release connector.
15. Inspect all parts by performing the "AFTER REPAIR PROCEDURE". (See AFTER REPAIR PROCEDURE.) See: Service and
Repair/Procedures/After Repair Procedure