Normal Operation
When the brake pedal is applied, the stoplamp switch allows voltage to flow through circuit (LG). Circuit (LG) provides voltage to the high mounted
stoplamp and the SJB. The SJB then provides power to the LH and RH rear lamps through circuits (LB/B) and (R/LG), respectively. All the stoplamp
are provided ground through circuit (B).
Possible Causes
-
circuit (LB/B) open or short to ground
-
circuit (B) open
-
circuit (LG) open
-
circuit (R/LG) open or short to ground
-
high mounted stoplamp
-
SJB
Pinpoint Test 3