6. Working through the glove compartment opening, detach the wire harness pin-type retainer above the evaporator discharge air temperature sensor.
7. Disconnect the RH temperature blend door actuator electrical connector.
CAUTION:Use care to avoid dropping the RH temperature blend door actuator screws into the plenum chamber when removing the screws. If a screw
is dropped into the plenum chamber, it may cause the airflow mode doors to jam, or may cause noise concerns.
8. Remove the 2 RH temperature blend door actuator screws.
-
To install, tighten to 3 Nm {0.3 kgf-m, 27 in-lbf}.
9. Remove the RH temperature blend door actuator.
NOTE:The RH center instrument panel duct must be slightly repositioned to allow access to the RH temperature blend door actuator screws.
10. To install, reverse the removal procedure.