Tribute 2WD L4-2.5L (2009)
Step 1-Step 3
Pinpoint Test 8: An Individual Demand Lamp Is Inoperative
PINPOINT TEST 8: AN INDIVIDUAL DEMAND LAMP IS INOPERATIVE
Normal Operation
When the battery saver relay is energized, voltage is supplied to the demand lamps through circuit (Y/G). The demand lamps are provided ground
through circuit (B/GY).
Possible Causes
-
Wiring, terminals or connectors
-
Sun visor
-
Lamp assembly
Diagnostic Procedure
CAUTION:Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.