mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Air Duct > < Temperature Blend Door Actuator - LH Removal/Installation|Page 4051
Page 3
background image

6. Working through the glove compartment opening, detach the wire harness pin-type retainer above the evaporator discharge air temperature sensor.

7. Disconnect the RH temperature blend door actuator electrical connector.

CAUTION: Use care to avoid dropping the RH temperature blend door actuator screws into the plenum chamber when removing the screws. If a screw
is dropped into the plenum chamber, it may cause the airflow mode doors to jam, or may cause noise concerns. 

8. Remove the 2 RH temperature blend door actuator screws.

-

To install, tighten to 3 Nm {0.3 kgf-m, 27 in-lbf}.

9. Remove the RH temperature blend door actuator.

NOTE: The RH center instrument panel duct must be slightly repositioned to allow access to the RH temperature blend door actuator screws. 

10. To install, reverse the removal procedure.

Air Duct > < Temperature Blend Door Actuator - LH Removal/Installation|Page 4051