Step 5

Pinpoint Test 2: The Turn Signal Lamps Are Always On

PINPOINT TEST 2: THE TURN SIGNAL LAMPS ARE ALWAYS ON

Normal Operation

The smart junction box (SJB) sends reference signals to the multifunction switch through circuit (BR/L) (LH turn input) and circuit (BR/W) (RH turn
input). When the multifunction switch is switched to the LH or RH TURN positions, the voltage signal is routed to ground. When the SJB detects the
multifunction switch in the LH or RH TURN position, the SJB sends voltage to the appropriate turn lamps.

-

DTC B2281 (Right Turn Switch Short to Ground) - an on-demand DTC that sets when the SJB detects a short to ground from the RH turn signal
switch input circuit.

-

DTC B2282 (Left Turn Switch Short to Ground) - an on-demand DTC that sets when the SJB detects a short to ground from the LH turn signal
switch input circuit.

Possible Causes

-

Wiring, terminals or connectors

-

Multifunction switch

-

SJB

Diagnostic Procedure

CAUTION: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector. 